Two-component epoxy primer «MasterPol-010 ЭП» consists of the base (component A) and hardener (component B) which are mixed before use.
Fields of application
Two-component epoxy primer is used for industrial and civil floors: commercial and industrial premises, food and pharmaceutical enterprises, warehouses, aircraft hangars, car repair shops and garages as well as residential and utility rooms.
The epoxy primer is used to remove dust of the concrete base, pores sealing, concrete top layer strengthening.
Primer is used to coat surfaces in the system of two-component polyurethane compound "MasterPol-210 ЭП (ТУ 20.30.22-015-69372620-2021)"
Instruction for use
Requirements for the base: concrete base properties and surface preparing methods must comply with the current construction and technical standards. The base must be strong, clean and dry, free of grease and dust (base moisture content is no more than 4 %).*
* Check more detailed information in Technical Specification.
Conditions
Temperature and air humidity in the room are the most important parameters in self-leveling floor production works. The room temperature should not be lower than +10°C and no more than +25 0C. Too low temperature slows down the rate of chemical reaction and makes spreading worse leading to increased material consumption and coating appearance deterioration. Too high temperature accelerates curing reaction and reduces the composition life. The relative humidity of the air in the room during the work is not more than 80%.
The process of applying
Preparation |
Component A (base) is mixed in a manufacturer's or special container, then component B (hardener) is added. Next, the components are thoroughly mixed for 2-3 minutes with a construction mixer. |
Proportions |
100:39 by weight 2,6:1 by volume |
Pot life at 20+20С, no less | 40 min |
Tools |
- two spindle construction mixer - velvet roller |
Cleaner |
Formula thinner RP-1K |
Cleaning |
Immediately after use |